Part Number Hot Search : 
20U20 IRFS74 IRHNA 2060C A48APR ZXCT1109 11200 1N5920B
Product Description
Full Text Search
 

To Download DRP024V120W1BX Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  technical d at asheet cliq ii din rail power supply 24v 120w 1 phase / drp024v120w1b all parameters are specified at 25 c ambient and ac input unless otherwise indicated. www. deltapsu .com ( may 2015 , rev. 04) 1 highligh ts & features C universal ac input voltage C power will not de - rate for the entire input voltage range C power boost of 150% for 5 seconds C full corrosion resistant aluminium chassis C conformal coating on pcba to protect against common dust and chemical pollutants C hazardous locations approval to atex and class i, div 2 (drp024v120w1ba) safety standards cb certified for worldwide use model number: drp0 24v 120w 1 b ? unit weight : 0. 72 kg dimensions (l x w x d): 121 x 50 x 12 3.1 mm general description the cliq ii din rail power supply series from one of the worlds leading power supply companies, delta electronics group, offers output voltage of 24v. these products are encased in rugged yet lightweight full aluminium body that can withstand shock and vibration according to iec 60068 - 2 standard. the series of single phase products can operate over a wide temperature range of - 25c to +80c. these products also feature universal ac input voltage range from 85vac to 264vac and the power will not de - rate throughout the entire range. another great feature is the conformal coating on the pcba which allows selected models to be certified to atex and class i, div 2 for use in hazardous locations. the design conforms to harmonic current emission iec/en 61000 - 3 - 2, class a. model information cliq ii din rail power supply model number input v oltage range output v oltage output cur r ent drp0 24v 120w 1 b ? 85- 264vac (120 - 375vdc) 24 vdc 5.00a model numbering dr p 0 24v 12 0w 1 b din rail power supply output voltage output power single phase cliq ii series a - metal case , with class i, div 2 n - metal case, without class i, div 2
technical d at asheet cliq ii din rail power supply 24v 120w 1 phase / drp024v120w1b all parameters are specified at 25 c ambient and ac input unless otherwise indicated. www. deltapsu .com ( may 2015 , rev. 04) 2 specifications input ratings / characteristics nominal input v oltage 100- 240 vac input v oltage range 85 - 264vac nominal input f r equency 50- 60hz input f r equency range 47- 63hz dc input voltage range * 120- 375vdc input cur r ent < 2.20a @ 115vac, < 1.10a @ 230vac e f ficiency at 100% load > 89 .0% @ 115vac, > 9 0 .0% @ 230vac max inrush cur r ent (cold start) < 35a @ 115 vac & 230vac leakage cur r ent < 1ma @ 240vac * *fulfills the test conditions for dc input. dc input safety approval can be obtained upon request. output ratings / characteristics nominal output voltage 24 vdc output voltage tolerance 2 % (initial set point tolerance from factory ) output voltage adjustment range 24- 28 output current 5.00 a (continuously operating at 24v ) 7.50 a (power boost for 5 seconds at 24 v, refer to the details in the functions section) output power 120 w (continuously operating at 24v ) 180 w (power boost for 5 seconds at 24v , refer to the details in the functions section) line regulation < 0.5 % typ. (@ 85 - 264 vac input , 100% load ) load regulation < 1 % typ. (@ 85 - 264 vac input , 0 - 100% load ) pard (20mhz) < 150 mvpp rise time < 100 ms @ nominal input (100% load) start - up time < 1 ,0 00ms @ nominal input (100% load ) hold - up time > 2 0ms @ 115 vac, > 115 ms @ 230 vac (100% load ) dynamic response (overshoot & undershoot o/p voltage) 5 % @ 0 - 100% load start - up with capacitive loads 10,0 00f max
technical d at asheet cliq ii din rail power supply 24v 120w 1 phase / drp024v120w1b all parameters are specified at 25 c ambient and ac input unless otherwise indicated. www. deltapsu .com ( may 2015 , rev. 04) 3 mechanical case cover / chassis aluminium dimensions (l x w x d) 121 x 50 x 1 2 3.1 mm unit weight 0. 72 kg indicator green led (dc ok) cooling system convection terminal input 3 pins (rated 3 00v/ 1 5 a ) output 4 pins (rated 300v/ 15a ) wire input / output awg 2 0 - 12 mounting rail standard ts35 din rail in accordance with en 60715 noise (1 meter from power supply) sound pressure level (spl) < 40dba environment surrounding air temperature operating - 2 5 c to + 80c (cold start at - 40c) storage - 40c to + 85c power de - rating vertical mounting > 5 0 c de - rate power by 2.5% / c horizontal mounting > 50 c de - rate power by 2.5% / c operating humidity 5 to 95 % rh (non - condensing) operating altitude 0 to 2 , 5 00 meters shock test ( non - operating) iec 60068 - 2 - 27 , 30g (300m/s 2) for a duration of 18ms, 1 time per direction, 2 times in total vibration ( non - operating) iec 60068 - 2 - 6, 10hz to 500hz @ 30m/s2 (3g peak); 60 min per axis for all x, y, z direction pollution degree 2 protections overvoltage < 32 v, 10%, selv output, hiccup mode , non - latching (auto - recovery) overload / overcurrent > 150 % of rated load current, hiccup mode, non - latching (auto - recovery) over temperature < 80 c surrounding air temperature @ 100% load, non - latching (auto - recovery) short circuit hiccup mode, non - latching (auto - recovery when the fault is removed) degree of protection ip20 protection against shock class i with pe* connection *pe: primary earth reliability data mtbf > 8 00,000 hrs. as per telcordia sr - 332 i/p: 115vac, o/p: 100% load, ta: 25c expected cap life time 10 years ( 115 vac & 230vac , 50% load @ 40c )
technical d at asheet cliq ii din rail power supply 24v 120w 1 phase / drp024v120w1b all parameters are specified at 25 c ambient and ac input unless otherwise indicated. www. deltapsu .com ( may 2015 , rev. 04) 4 safety standards / directives electrical equipment in power installations en 50178 / iec 62103 electrical safety siq to en 60950 - 1, ul/cul recognized to ul 60950 - 1 and csa c22.2 no. 60950 - 1 (file no. e191395) , cb scheme to iec 60950 - 1 industrial control equipment ul/cul listed to ul 508 and csa c22.2 no. 107.1 - 01 (file no. e315355) , csa to csa c22.2 no. 107.1 - 01 (file no. 181564) hazardous location / atex (for drp0 24v 12 0w1ba) ccsaus to csa c22.2 no. 213 - m1987, ansi / isa 12.12.01:20 11 [class i, division 2, group a, b, c, d t4, ta= - 25c to +80c (> +50c derating)] en 60079 - 0:2009, en 60079 - 15:2010 [ ii 3g ex na nc iic t4 gc, ta= - 25c to +80c (> +50c derating)] ii 3g atex 94/9/ec (for drp0 24v 12 0w1ba) certificate no. eps 12 atex 1 491 x ccc gb9254, gb17625.1 and gb4943.1 ? 2000m ?? ce in conformance with emc directive 2004/108/ec and low voltage directive 2006/95/ec for drp0 24 v 12 0w1ba: in conformance with equipment for explosive atmospheres (atex) directive 94/9/ec material and parts rohs directive 2011/65/eu compliant galvanic isolation input to output 4 .0 kvac input to ground 1.5kvac output to ground 1.5kvac
technical d at asheet cliq ii din rail power supply 24v 120w 1 phase / drp024v120w1b all parameters are specified at 25 c ambient and ac input unless otherwise indicated. www. deltapsu .com ( may 2015 , rev. 04) 5 emc emc / emissions cispr 22, en 55022, cispr 11, en 55011, fcc title 47: class b component power supply for general use en 61204 - 3 immunity to en 55024, en 61000 - 6 - 1, en 61000 - 6 - 2 electrostatic discharge iec 61000 - 4 - 2 level 4 criteria a 1) air discharge: 15kv contact discharge: 8kv radiated field iec 61000 - 4 - 3 level 3 criteria a 1) 80mhz - 1ghz, 10v/m, 80% modulation (1khz) electrical fast transient / burst iec 61000 - 4 - 4 level 3 criteria a 1) 2kv surge iec 61000 - 4 - 5 level 3 criteria a 1) common mode 2) : 2kv differential mode 3) : 1kv conducted iec 61000 - 4 - 6 level 3 criteria a 1) 150khz - 80mhz, 10vrms power frequency magnetic fields iec 61000 - 4 - 8 criteria a 1) 3 0a/meter voltage dips iec 61000 - 4 - 11 100% dip; 1 cycle (20ms); self recoverable low energy pulse test (ring wave) iec 61000 - 4 - 12 level 3 criteria a 1) common mode 2) : 2kv differential mode 3) : 1kv harmonic current emission iec/en 61000 - 3 - 2, class a voltage fluctuation and flicker iec/en 61000 - 3 - 3 1) criteria a: normal performance within the specification limits 2) asymmetrical: common mode (line to earth) 3) symmetrical: differential mode (line to line)
technical d at asheet cliq ii din rail power supply 24v 120w 1 phase / drp024v120w1b all parameters are specified at 25 c ambient and ac input unless otherwise indicated. www. deltapsu .com ( may 2015 , rev. 04) 6 block diagram
technical d at asheet cliq ii din rail power supply 24v 120w 1 phase / drp024v120w1b all parameters are specified at 25 c ambient and ac input unless otherwise indicated. www. deltapsu .com ( may 2015 , rev. 04) 7 device description 1 ) input terminal block connector 2 ) output terminal block connector 3 ) dc voltage adjustment potentiometer 4 ) dc ok control led (green) 5 ) universal mounting rail system dimensions l x w x d: 121 x 50 x 12 3.1 mm
technical d at asheet cliq ii din rail power supply 24v 120w 1 phase / drp024v120w1b all parameters are specified at 25 c ambient and ac input unless otherwise indicated. www. deltapsu .com ( may 2015 , rev. 04) 8 engineering data de- rating output de - rating vs. input voltage note 1 . power supply components may degrade, or be damaged, when the power supply is continuously used outside the shaded region, refer to the graph shown in fig. 1. 2 . if the output capacity is not reduced when the surrounding air temperature > 5 0c, the device ma y run into over temperature protection. when activated, the output voltage will go into bouncing mode and will recover when the surrounding air temperature is lowered or the load is reduced as far as necessary to keep the device in working condition. 3 . in o rder for the device to function in the manner intended, it is also necessary to keep a safety distance of 20mm (for vertical mounting) or 50mm (for horizontal mounting) with adjacent units while the device is in operation . 4 . depending on the surrounding air temperature and output load delivered by the power supply, the device can be very hot! 5 . if the device has to be mounted in any other orientation, please do not hesitate to contact info@deltapsu.com for more details. fig. 1 de - rating for vertical and horizontal mounting orientation > 50 c de - rate power by 2.5% / c ? no output power de - rating across the entire input voltage range
technical d at asheet cliq ii din rail power supply 24v 120w 1 phase / drp024v120w1b all parameters are specified at 25 c ambient and ac input unless otherwise indicated. www. deltapsu .com ( may 2015 , rev. 04) 9 assembly & installation the power supply unit (psu) can be mounted on 35mm din rails in accordance with en 60715. t he device should be installed with input terminal block at the bottom. each device is delivered ready to install. mounting dismounting fig. 2.1 mounting snap on the din rail as shown in fig. 2.1: 1 . tilt the unit upwards and insert it onto the din rail. 2 . push downwards until stopped. 3 . press against the bottom front side for locking. 4 . shake the unit slightly to ensure that it is secured. fig. 2.2 dismounting to uninstall, pull or slide down the latch with screw driver as shown in fig. 2.2. then slide the power supply unit (psu) in the opposite direction, release the latch and pull out the power supply unit (psu) from the rail. caution: must tighten wire to housing (fig. 3.1) before plugging into the terminal block connection (fig. 3.2). in accordance to en 60950 / ul 50950, flexible cables require ferrules. use appropriate copper cables designed to sustain operating temperature of 60c / 75c or more to fulfill ul requirements. connection fig. 3.1 fig. 3.2
technical d at asheet cliq ii din rail power supply 24v 120w 1 phase / drp024v120w1b all parameters are specified at 25 c ambient and ac input unless otherwise indicated. www. deltapsu .com ( may 2015 , rev. 04) 10 safety instructions ? vertical mounting C always switch mains of input power off before connecting and disconnecting the input voltage to the unit. if mains are not turned off, there is risk of explosion / severe damage. C to guarantee sufficient convection cooling, keep a distance of 50mm above and below the device as well as a lateral distanc e of 20mm (for vertical mounting) or 50mm (for horizontal mounting) to other units. C note that the enclosure of the device can become very hot depending on the surrounding air temperature and load of the power supply. risk of burns! C only plug in and unplug connectors when power is turned off! C do not insert any objects into the unit. C hazardous voltages may be present for up to 5 minutes after the input mains voltage is disconnected. do not touch the unit du ring this time. C the power supplies are built in units and must be installed in a cabinet or room (condensation free environment and indoor location) that is relatively free of conductive contaminants. C caution: for use in a controlled environment. for drp0 24v 12 0w1ba: C the power supplies unit must be installed in an ip54 enclosure or cabinet in the final installation. the enclosure or cabinet must comply with en 60079 - 0 or en 60079 - 15. C warning: explosion hazard - substitution of components may impair suitability for class i, division 2. C warning: explos ion hazard - do not disconnect equipment or adjust potentiometer unless the power has been switched off or the area is known to be non - hazardous. ? horizontal mounting
technical d at asheet cliq ii din rail power supply 24v 120w 1 phase / drp024v120w1b all parameters are specified at 25 c ambient and ac input unless otherwise indicated. www. deltapsu .com ( may 2015 , rev. 04) 11 functions graph illustrating the start - up time, rise time, and hold - up time start - up time the time required for the output voltage to reach 90% of its set value, after the input voltage is applied. rise time the time required for the output voltage to change from 10% to 90% of its set value. hold - up time hold up time is the time when the ac input collapses and output voltage retains regulation for a certain period of time. the time required for the output to reach 9 0 % of its set value, after the input voltage is removed. inrush current inrush current is the peak, instan taneous, input current measured and, occurs when the input voltage is first applied. for ac input voltages, the maximum peak value of inrush current will occur during the first half cycle of the applied ac voltage. this peak value decreases exponenti ally during subsequent cycles of ac voltage. dynamic response the power supply output voltage will remains within 5 % of its steady state value, when subjected to a dynamic load from 0 to 100% of its rated current.
technical d at asheet cliq ii din rail power supply 24v 120w 1 phase / drp024v120w1b all parameters are specified at 25 c ambient and ac input unless otherwise indicated. www. deltapsu .com ( may 2015 , rev. 04) 12 power boost ???? ????? ( % ) = ? ? ????? ???? ??????? ?????? ????? ( ? ??? ) = ( ????? ????? ? ? ) + ( ??? - ???? ????? ? ? ) ????? ???? or ??? - ???? ????? = ? ? ??? ????? ???? ? ? ( ????? ????? ? ? ) ? ? an example of power boost and average output power power boost peak power (w p ) power boost duration (t p ) duty cycle non - peak power (w n ) non - peak power duration (t n ) total time (t) 150% 180 5 sec 10% 113w 45 sec 50 sec 150% 180 5 sec 35% 88w 9.3 sec 14.3 sec 120% 144 10 sec 20% 114w 40 sec 50 sec 120% 1 4 4 10 sec 35% 107w 18.5 sec 28.5 sec it is not recommended to prolong the duration of power boost to be longer than the specified duty cycle calculation, this may cause damage to the psu. power boost is the reserve power available constantly that allows reliable startup to support sudden and short spike of loads with high inrush current typically during turn on to remove the need of more expensive higher rated power supply unit. after the o utput has reached its steady state set value, the power supply can support surge loads with a higher short - term power demand up to 15 0% of maximum rated load (i o max), for a maximum duration of 5 seconds. the power boost is also available to repeatedly bas is with according to the condition of an average (r.m.s) output power shall not exceed continuous operating condition or refer to duty cycle calculation below.
technical d at asheet cliq ii din rail power supply 24v 120w 1 phase / drp024v120w1b all parameters are specified at 25 c ambient and ac input unless otherwise indicated. www. deltapsu .com ( may 2015 , rev. 04) 13 overload & overcurrent protections the power supplys overload (olp) and overcurrent (ocp) protections will be activated when output current exceeds 1 50% of i o (max load). in such occurrence, the v o will start to droop and once the power supply has reached its maximum power limit, the protection is activated and the power supply will go into hiccup mode (auto - recovery). the power supply will recover once the fault condition of the olp and ocp is removed and i o is back within the specifications. it is not recommended to prolong the duration of i o when it is <150% but >100%, since it may cause damage to the psu. short circuit protection the power supplys output olp/ocp function also provides protection against short circuits. when a short circuit is applied, the output current will operate in hiccup mode, as shown in the illustration in the olp/ocp section on this page. the power supply will return to normal operation after the short circuit is removed. overvoltage protection the power supplys over voltage circuit will be activated when its internal feedback circuit fails. the output voltage shall not exceed its specifications defined on page 3 under protections. over temperature protection as mentioned above, the power supply also has over temperature protection (otp). i n the event of a higher operating temperature at 100% load , the power supply will run into otp when the operating temperature is beyond what is recommended in the de - rating g raph. when activated, the output voltage will go into bouncing mode until the temperature drops to its normal operating temperature as recom mended in the de - rating graph .
technical d at asheet cliq ii din rail power supply 24v 120w 1 phase / drp024v120w1b all parameters are specified at 25 c ambient and ac input unless otherwise indicated. www. deltapsu .com ( may 2015 , rev. 04) 14 operating mode ? redundancy operation in order to ensure proper redundancy operation for the power supply unit (psu), ensure that the output voltage difference bet ween the two units is kept at 0.45 ~ 0.50v for 24v suppli es. follow simple steps given below to verify: step 1. measure output voltage of psu 1 and psu 2. if psu 1 is the master unit, then v o of psu 1 must be higher than psu 2. in order to set the output voltage, connect the power supply to 50% load and set the psu 1 and psu 2 output voltage. step 2. connect the right drr module, 20a as per the system requirement to the power supply units psu 1 and psu 2 at v in 1 & v in 2 respectively. step 3. connect the system load from v out . please note that output voltag e v out from drr module will be = v o (output voltage of power supply) C v drop * (in drr module). ? parallel operation these drr modules can also be used for parallel function in order to increase the output power by n+1 (e.g. 2.5a + 2.5a = 5a or 2.5a + 2.5a + 2.5a = 7.5a) or current sharing, and thus increasing the power supply and system reliability. though the drp0 24 v 12 0w1b is not designed for current sharing, a good current sharing between two power supplies can be achieved by following simple st eps as below (refer to fig. 4 for the connection diagram). step 1 . set output load condition for both supplies at 50% and measure the output voltages. step 2. adjust output voltages to the same level or within 25mv difference. step 3 . connect psu 1 and psu 2 with the drr - 20a module and measure at v in 1 & v in 2 to verify the voltage difference. ensure the voltages are within 25mv. step 4 . output voltage from drr module v out will be = v o (output voltage of power supply) C v drop * (in drr module). *v drop will vary from 0.60v to 0.90v (typical 0.65v) depending on the load current and surrounding air temperature. fig. 4 redundancy / parallel operation connection diagram
technical d at asheet cliq ii din rail power supply 24v 120w 1 phase / drp024v120w1b all parameters are specified at 25 c ambient and ac input unless otherwise indicated. www. deltapsu .com ( may 2015 , rev. 04) 15 others delta rohs compliant restriction of the usage of hazardous substances the european directive 2011/65/e u limits the maximum impurity level of homogeneous materials such as lead, mercury, cadmium, chrome, polybrominated flame retardants pbb and pbde for the use in electrical and electronic equipment. rohs is the abbreviation for restriction of the use of certain hazardous substances in electrical and electronic equipment. this product conforms to this standard. conformal coating the protective coating technology delta electronics group has designed the perfect dipping technique which penetrates everywhere including under device, and prevents leakage. the conformal coating dipping can be applied to pcb a s or circuit board. the coating preserves the performance of precisio n electronic primarily by preventing ionizable contaminants such as salt from reaching circuit nodes, where the material slumps around sharp edges. this can be a problem especially in highly conversing atmosphere. pfc C norm e n 61000 -3 -2 line current harmonic content typically, the input current waveform is not sinusoidal due to the periodical peak charging of the input capacitor. in industrial environment, complying with en 61000 - 3 - 2 is only necessary under special conditions. complying to this standard can have some technical drawbacks, such as lower efficiency as well as some commercial aspects such as higher purchasing costs. frequently, the user does not profit from fulfilling this standard, therefore, it is important to know whether it is mandatory to meet this st andard for a specific application.


▲Up To Search▲   

 
Price & Availability of DRP024V120W1BX

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X